Siemens SIMATIC Step 7 (TIA Portal) 15.0

CPE Details

Siemens SIMATIC Step 7 (TIA Portal) 15.0
15.0
2018-10-09
13h52 +00:00
2021-06-15
19h24 +00:00
Alerte pour un CPE
Restez informé de toutes modifications pour un CPE spécifique.
Gestion des notifications

CPE Name: cpe:2.3:a:siemens:simatic_step_7_\(tia_portal\):15.0:*:*:*:*:*:*:*

Informations

Vendor

siemens

Product

simatic_step_7_\(tia_portal\)

Version

15.0

Related CVE

Open and find in CVE List

CVE ID Publié Description Score Gravité
CVE-2018-13811 2018-12-13 15h00 +00:00 A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All Versions < V15.1). Password hashes with insufficient computational effort could allow an attacker to access to a project file and reconstruct passwords. The vulnerability could be exploited by an attacker with local access to the project file. No user interaction is required to exploit the vulnerability. The vulnerability could allow the attacker to obtain certain passwords from the project. At the time of advisory publication no public exploitation of this vulnerability was known.
5.5
Moyen
CVE-2018-11453 2018-08-07 15h00 +00:00 A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions < V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 6), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (All versions < V15 Update 2). Improper file permissions in the default installation of TIA Portal may allow an attacker with local file system access to insert specially crafted files which may prevent TIA Portal startup (Denial-of-Service) or lead to local code execution. No special privileges are required, but the victim needs to attempt to start TIA Portal after the manipulation.
7.8
Haute
CVE-2018-11454 2018-08-07 15h00 +00:00 A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions < V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 6), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (All versions < V15 Update 2). Improper file permissions in the default installation of TIA Portal may allow an attacker with local file system access to manipulate resources which may be transferred to devices and executed there by a different user. No special privileges are required, but the victim needs to transfer the manipulated files to a device. Execution is caused on the target device rather than on the PG device.
8.6
Haute