Siemens SIPLUS NET SCALANCE X202-2P IRT

CPE Details

Siemens SIPLUS NET SCALANCE X202-2P IRT
-
2022-10-14
11h50 +00:00
2022-10-14
20h00 +00:00
Alerte pour un CPE
Restez informé de toutes modifications pour un CPE spécifique.
Gestion des notifications

CPE Name: cpe:2.3:h:siemens:siplus_net_scalance_x202-2p_irt:-:*:*:*:*:*:*:*

Informations

Vendor

siemens

Product

siplus_net_scalance_x202-2p_irt

Version

-

Related CVE

Open and find in CVE List

CVE ID Publié Description Score Gravité
CVE-2023-29054 2023-04-11 09h03 +00:00 A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT PRO (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2P IRT (All versions < V5.5.2), SCALANCE X202-2P IRT PRO (All versions < V5.5.2), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT PRO (All versions < V5.5.2), SCALANCE XF201-3P IRT (All versions < V5.5.2), SCALANCE XF202-2P IRT (All versions < V5.5.2), SCALANCE XF204-2BA IRT (All versions < V5.5.2), SCALANCE XF204IRT (All versions < V5.5.2), SIPLUS NET SCALANCE X202-2P IRT (All versions < V5.5.2). The SSH server on affected devices is configured to offer weak ciphers by default. This could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data passed over the connection between legitimate clients and the affected device.
7.4
Haute
CVE-2022-40631 2022-10-10 22h00 +00:00 A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.0), SCALANCE X201-3P IRT (All versions < V5.5.0), SCALANCE X201-3P IRT PRO (All versions < V5.5.0), SCALANCE X202-2IRT (All versions < V5.5.0), SCALANCE X202-2P IRT (All versions < V5.5.0), SCALANCE X202-2P IRT PRO (All versions < V5.5.0), SCALANCE X204-2 (All versions < V5.2.5), SCALANCE X204-2FM (All versions < V5.2.5), SCALANCE X204-2LD (All versions < V5.2.5), SCALANCE X204-2LD TS (All versions < V5.2.5), SCALANCE X204-2TS (All versions < V5.2.5), SCALANCE X204IRT (All versions < V5.5.0), SCALANCE X204IRT PRO (All versions < V5.5.0), SCALANCE X206-1 (All versions < V5.2.5), SCALANCE X206-1LD (All versions < V5.2.5), SCALANCE X208 (All versions < V5.2.5), SCALANCE X208PRO (All versions < V5.2.5), SCALANCE X212-2 (All versions < V5.2.5), SCALANCE X212-2LD (All versions < V5.2.5), SCALANCE X216 (All versions < V5.2.5), SCALANCE X224 (All versions < V5.2.5), SCALANCE XF201-3P IRT (All versions < V5.5.0), SCALANCE XF202-2P IRT (All versions < V5.5.0), SCALANCE XF204 (All versions < V5.2.5), SCALANCE XF204-2 (All versions < V5.2.5), SCALANCE XF204-2BA IRT (All versions < V5.5.0), SCALANCE XF204IRT (All versions < V5.5.0), SCALANCE XF206-1 (All versions < V5.2.5), SCALANCE XF208 (All versions < V5.2.5), SIPLUS NET SCALANCE X202-2P IRT (All versions < V5.5.0). There is a cross-site scripting vulnerability on the affected devices, that if used by a threat actor, it could result in session hijacking.
6.1
Moyen