Juniper QFX5130

CPE Details

Juniper QFX5130
-
2020-12-21
17h41 +00:00
2020-12-21
17h41 +00:00
Alerte pour un CPE
Restez informé de toutes modifications pour un CPE spécifique.
Gestion des notifications

CPE Name: cpe:2.3:h:juniper:qfx5130:-:*:*:*:*:*:*:*

Informations

Vendor

juniper

Product

qfx5130

Version

-

Related CVE

Open and find in CVE List

CVE ID Publié Description Score Gravité
CVE-2024-21595 2024-01-12 00h52 +00:00 An Improper Validation of Syntactic Correctness of Input vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS allows a network-based, unauthenticated attacker to cause a Denial of Service (DoS). If an attacker sends high rate of specific ICMP traffic to a device with VXLAN configured, this causes a deadlock of the PFE and results in the device becoming unresponsive. A manual restart will be required to recover the device. This issue only affects EX4100, EX4400, EX4600, QFX5000 Series devices. This issue affects: Juniper Networks Junos OS * 21.4R3 versions earlier than 21.4R3-S4; * 22.1R3 versions earlier than 22.1R3-S3; * 22.2R2 versions earlier than 22.2R3-S1; * 22.3 versions earlier than 22.3R2-S2, 22.3R3; * 22.4 versions earlier than 22.4R2; * 23.1 versions earlier than 23.1R2.
7.5
Haute
CVE-2023-44203 2023-10-12 23h06 +00:00 An Improper Check or Handling of Exceptional Conditions vulnerability in the Packet Forwarding Engine (pfe) of Juniper Networks Junos OS on QFX5000 Series, EX2300, EX3400, EX4100, EX4400 and EX4600 allows a adjacent attacker to send specific traffic, which leads to packet flooding, resulting in a Denial of Service (DoS). When a specific IGMP packet is received in an isolated VLAN, it is duplicated to all other ports under the primary VLAN, which causes a flood. This issue affects QFX5000 series, EX2300, EX3400, EX4100, EX4400 and EX4600 platforms only. This issue affects Juniper Junos OS on on QFX5000 Series, EX2300, EX3400, EX4100, EX4400 and EX4600: * All versions prior to 20.4R3-S5; * 21.1 versions prior to 21.1R3-S4; * 21.2 versions prior to 21.2R3-S3; * 21.3 versions prior to 21.3R3-S5; * 21.4 versions prior to 21.4R3-S2; * 22.1 versions prior to 22.1R3; * 22.2 versions prior to 22.2R3; * 22.3 versions prior to 22.3R2.
6.5
Moyen
CVE-2023-28984 2023-04-17 00h00 +00:00 A Use After Free vulnerability in the Layer 2 Address Learning Manager (l2alm) of Juniper Networks Junos OS on QFX Series allows an adjacent attacker to cause the Packet Forwarding Engine to crash and restart, leading to a Denial of Service (DoS). The PFE may crash when a lot of MAC learning and aging happens, but due to a Race Condition (Concurrent Execution using Shared Resource with Improper Synchronization) that is outside the attackers direct control. This issue affects: Juniper Networks Junos OS versions prior to 19.4R3-S10 on QFX Series; 20.2 versions prior to 20.2R3-S7 on QFX Series; 20.3 versions prior to 20.3R3-S6 on QFX Series; 20.4 versions prior to 20.4R3-S5 on QFX Series; 21.1 versions prior to 21.1R3-S4 on QFX Series; 21.2 versions prior to 21.2R3-S3 on QFX Series; 21.3 versions prior to 21.3R3-S3 on QFX Series; 21.4 versions prior to 21.4R3 on QFX Series; 22.1 versions prior to 22.1R3 on QFX Series; 22.2 versions prior to 22.2R2 on QFX Series.
5.3
Moyen
CVE-2023-22405 2023-01-11 23h00 +00:00 An Improper Preservation of Consistency Between Independent Representations of Shared State vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS allows an adjacent, unauthenticated attacker to cause a Denial of Service (DoS) to device due to out of resources. When a device is configured with "service-provider/SP style" switching, and mac-limiting is configured on an Aggregated Ethernet (ae) interface, and then a PFE is restarted or the device is rebooted, mac-limiting doesn't work anymore. Please note that the issue might not be apparent as traffic will continue to flow through the device although the mac table and respective logs will indicate that mac limit is reached. Functionality can be restored by removing and re-adding the MAC limit configuration. This issue affects Juniper Networks Junos OS on QFX5k Series, EX46xx Series: All versions prior to 20.2R3-S5; 20.3 versions prior to 20.3R3-S5; 20.4 versions prior to 20.4R3-S4; 21.1 versions prior to 21.1R3-S3; 21.2 versions prior to 21.2R3-S1; 21.3 versions prior to 21.3R3 on; 21.4 versions prior to 21.4R3 on; 22.1 versions prior to 22.1R2 on.
6.5
Moyen
CVE-2022-22226 2022-10-18 02h46 +00:00 In VxLAN scenarios on EX4300-MP, EX4600, QFX5000 Series devices an Uncontrolled Memory Allocation vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS allows an unauthenticated adjacently located attacker sending specific packets to cause a Denial of Service (DoS) condition by crashing one or more PFE's when they are received and processed by the device. Upon automatic restart of the PFE, continued processing of these packets will cause the memory leak to reappear. Depending on the volume of packets received the attacker may be able to create a sustained Denial of Service (DoS) condition. This issue affects: Juniper Networks Junos OS on EX4300-MP, EX4600, QFX5000 Series: 17.1 version 17.1R1 and later versions prior to 17.3R3-S12; 17.4 versions prior to 17.4R2-S13, 17.4R3-S5; 18.1 versions prior to 18.1R3-S13; 18.2 versions prior to 18.2R3-S8; 18.3 versions prior to 18.3R3-S5; 18.4 versions prior to 18.4R1-S8, 18.4R2-S6, 18.4R3-S6; 19.1 versions prior to 19.1R3-S4; 19.2 versions prior to 19.2R1-S7, 19.2R3-S1; 19.3 versions prior to 19.3R2-S6, 19.3R3-S1; 19.4 versions prior to 19.4R1-S4, 19.4R2-S4, 19.4R3-S1; 20.1 versions prior to 20.1R2; 20.2 versions prior to 20.2R2-S3, 20.2R3; 20.3 versions prior to 20.3R2. This issue does not affect Junos OS versions prior to 17.1R1.
6.5
Moyen
CVE-2022-22210 2022-07-20 14h15 +00:00 A NULL Pointer Dereference vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS on QFX5000 Series and MX Series allows an unauthenticated adjacent attacker to cause a Denial of Service (DoS). On QFX5K Series and MX Series, when the PFE receives a specific VxLAN packet the Layer 2 Address Learning Manager (L2ALM) process will crash leading to an FPC reboot. Continued receipt of this specific packet will create a sustained Denial of Service (DoS) condition. This issue affects Juniper Networks Junos OS on QFX5000 Series, MX Series: 20.3 versions prior to 20.3R3-S3; 20.4 versions prior to 20.4R3-S2; 21.2 versions prior to 21.2R2-S1. This issue does not affect Juniper Networks Junos OS: All versions prior to 20.3R1; 21.1 version 21.1R1 and later versions.
6.5
Moyen
CVE-2022-22203 2022-07-20 14h11 +00:00 An Incorrect Comparison vulnerability in PFE of Juniper Networks Junos OS allows an adjacent unauthenticated attacker to cause a Denial of Service (DoS). On QFX5000 Series, and EX4600 and EX4650 platforms, the fxpc process will crash followed by the FPC reboot upon receipt of a specific hostbound packet. Continued receipt of these specific packets will create a sustained Denial of Service (DoS) condition. This issue only affects Juniper Networks Junos OS 19.4 version 19.4R3-S4.
6.5
Moyen
CVE-2022-22174 2022-01-19 00h21 +00:00 A vulnerability in the processing of inbound IPv6 packets in Juniper Networks Junos OS on QFX5000 Series and EX4600 switches may cause the memory to not be freed, leading to a packet DMA memory leak, and eventual Denial of Service (DoS) condition. Once the condition occurs, further packet processing will be impacted, creating a sustained Denial of Service (DoS) condition. The following error logs may be observed using the "show heap" command and the device may eventually run out of memory if such packets are received continuously. Jan 12 12:00:00 device-name fpc0 (buf alloc) failed allocating packet buffer Jan 12 12:00:01 device-name fpc0 (buf alloc) failed allocating packet buffer user@device-name> request pfe execute target fpc0 timeout 30 command "show heap" ID Base Total(b) Free(b) Used(b) % Name -- ---------- ----------- ----------- ----------- --- ----------- 0 246fc1a8 536870488 353653752 183216736 34 Kernel 1 91800000 16777216 12069680 4707536 28 DMA 2 92800000 75497472 69997640 5499832 7 PKT DMA DESC 3 106fc000 335544320 221425960 114118360 34 Bcm_sdk 4 97000000 176160768 200 176160568 99 Packet DMA <<<<<<<<<<<<<< 5 903fffe0 20971504 20971504 0 0 Blob This issue affects Juniper Networks Junos OS on QFX5000 Series, EX4600: 18.3R3 versions prior to 18.3R3-S6; 18.4 versions prior to 18.4R2-S9, 18.4R3-S9; 19.1 versions prior to 19.1R2-S3, 19.1R3-S7; 19.2 versions prior to 19.2R1-S8, 19.2R3-S3; 19.3 versions prior to 19.3R2-S7, 19.3R3-S4; 19.4 versions prior to 19.4R2-S5, 19.4R3-S6; 20.1 versions prior to 20.1R3-S1; 20.2 versions prior to 20.2R3-S2; 20.3 versions prior to 20.3R3-S1; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R2-S1, 21.1R3; 21.2 versions prior to 21.2R1-S1, 21.2R2. This issue does not affect Juniper Networks Junos OS: Any versions prior to 17.4R3; 18.1 versions prior to 18.1R3-S6; 18.2 versions prior to 18.2R3; 18.3 versions prior to 18.3R3; 18.4 versions prior to 18.4R2; 19.1 versions prior to 19.1R2.
7.5
Haute
CVE-2021-31370 2021-10-19 18h17 +00:00 An Incomplete List of Disallowed Inputs vulnerability in Packet Forwarding Engine (PFE) of Juniper Networks Junos OS on QFX5000 Series and EX4600 Series allows an adjacent unauthenticated attacker which sends a high rate of specific multicast traffic to cause control traffic received from the network to be dropped. This will impact control protocols (including but not limited to routing-protocols) and lead to a Denial of Service (DoS). Continued receipt of this specific multicast traffic will create a sustained Denial of Service (DoS) condition. This issue affects Juniper Networks Junos OS on QFX5000 and EX4600 Series: All versions prior to 17.3R3-S12; 17.4 versions prior to 17.4R3-S5; 18.3 versions prior to 18.3R3-S5; 18.4 versions prior to 18.4R3-S9; 19.1 versions prior to 19.1R3-S6; 19.2 versions prior to 19.2R1-S7, 19.2R3-S3; 19.3 versions prior to 19.3R2-S6, 19.3R3-S3; 19.4 versions prior to 19.4R1-S4, 19.4R3-S3; 20.1 versions prior to 20.1R2-S2, 20.1R3-S1; 20.2 versions prior to 20.2R3-S2; 20.3 versions prior to 20.3R3; 20.4 versions prior to 20.4R2-S2, 20.4R3; 21.1 versions prior to 21.1R1-S1, 21.1R2.
6.5
Moyen
CVE-2021-31361 2021-10-19 18h16 +00:00 An Improper Check for Unusual or Exceptional Conditions vulnerability combined with Improper Handling of Exceptional Conditions in Juniper Networks Junos OS on QFX Series and PTX Series allows an unauthenticated network based attacker to cause increased FPC CPU utilization by sending specific IP packets which are being VXLAN encapsulated leading to a partial Denial of Service (DoS). Continued receipted of these specific traffic will create a sustained Denial of Service (DoS) condition. This issue affects: Juniper Networks Junos OS on QFX Series: All versions prior to 17.3R3-S11; 17.4 versions prior to 17.4R2-S13, 17.4R3-S4; 18.1 versions prior to 18.1R3-S12; 18.2 versions prior to 18.2R2-S8, 18.2R3-S7; 18.3 versions prior to 18.3R3-S4; 18.4 versions prior to 18.4R1-S8, 18.4R2-S7, 18.4R3-S7; 19.1 versions prior to 19.1R1-S6, 19.1R2-S2, 19.1R3-S4; 19.2 versions prior to 19.2R1-S6, 19.2R3-S2; 19.3 versions prior to 19.3R3-S1; 19.4 versions prior to 19.4R2-S3, 19.4R3-S1; 20.1 versions prior to 20.1R2, 20.1R3; 20.2 versions prior to 20.2R2, 20.2R3; 20.3 versions prior to 20.3R1-S1, 20.3R2. Juniper Networks Junos OS on PTX Series: All versions prior to 18.4R3-S9; 19.1 versions prior to 19.1R3-S6; 19.2 versions prior to 19.2R1-S7, 19.2R3-S3; 19.3 versions prior to 19.3R2-S6, 19.3R3-S3; 19.4 versions prior to 19.4R1-S4, 19.4R3-S5; 20.1 versions prior to 20.1R2-S2, 20.1R3; 20.2 versions prior to 20.2R3-S1; 20.3 versions prior to 20.3R2-S1, 20.3R3; 20.4 versions prior to 20.4R2-S1, 20.4R3; 21.1 versions prior to 21.1R1-S1, 21.1R2.
5.3
Moyen
CVE-2021-0289 2021-07-15 20h01 +00:00 When user-defined ARP Policer is configured and applied on one or more Aggregated Ethernet (AE) interface units, a Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability between the Device Control Daemon (DCD) and firewall process (dfwd) daemons of Juniper Networks Junos OS allows an attacker to bypass the user-defined ARP Policer. In this particular case the User ARP policer is replaced with default ARP policer. To review the desired ARP Policers and actual state one can run the command "show interfaces <> extensive" and review the output. See further details below. An example output is: show interfaces extensive | match policer Policer: Input: __default_arp_policer__ <<< incorrect if user ARP Policer was applied on an AE interface and the default ARP Policer is displayed Policer: Input: jtac-arp-ae5.317-inet-arp <<< correct if user ARP Policer was applied on an AE interface For all platforms, except SRX Series: This issue affects Juniper Networks Junos OS: All versions 5.6R1 and all later versions prior to 18.4 versions prior to 18.4R2-S9, 18.4R3-S9 with the exception of 15.1 versions 15.1R7-S10 and later versions; 19.4 versions prior to 19.4R3-S3; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R3-S2; 20.3 version 20.3R1 and later versions; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R2; This issue does not affect Juniper Networks Junos OS versions prior to 5.6R1. On SRX Series this issue affects Juniper Networks Junos OS: 18.4 versions prior to 18.4R2-S9, 18.4R3-S9; 19.4 versions prior to 19.4R3-S4; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R3-S2; 20.3 version 20.3R1 and later versions; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R2. This issue does not affect 18.4 versions prior to 18.4R1 on SRX Series. This issue does not affect Junos OS Evolved.
6.5
Moyen
CVE-2021-0285 2021-07-15 20h00 +00:00 An uncontrolled resource consumption vulnerability in Juniper Networks Junos OS on QFX5000 Series and EX4600 Series switches allows an attacker sending large amounts of legitimate traffic destined to the device to cause Interchassis Control Protocol (ICCP) interruptions, leading to an unstable control connection between the Multi-Chassis Link Aggregation Group (MC-LAG) nodes which can in turn lead to traffic loss. Continued receipt of this amount of traffic will create a sustained Denial of Service (DoS) condition. An indication that the system could be impacted by this issue is the following log message: "DDOS_PROTOCOL_VIOLATION_SET: Warning: Host-bound traffic for protocol/exception LOCALNH:aggregate exceeded its allowed bandwidth at fpc for times, started at " This issue affects Juniper Networks Junos OS on QFX5000 Series and EX4600 Series: 15.1 versions prior to 15.1R7-S9; 17.3 versions prior to 17.3R3-S11; 17.4 versions prior to 17.4R2-S13, 17.4R3-S5; 18.3 versions prior to 18.3R3-S5; 18.4 versions prior to 18.4R2-S8, 18.4R3-S7; 19.1 versions prior to 19.1R3-S5; 19.2 versions prior to 19.2R1-S6, 19.2R3-S2; 19.3 versions prior to 19.3R2-S6, 19.3R3-S2; 19.4 versions prior to 19.4R1-S4, 19.4R2-S4, 19.4R3-S2; 20.1 versions prior to 20.1R2-S2, 20.1R3; 20.2 versions prior to 20.2R2-S3, 20.2R3; 20.3 versions prior to 20.3R2; 20.4 versions prior to 20.4R1-S1, 20.4R2.
7.5
Haute
CVE-2021-0259 2021-04-22 19h37 +00:00 Due to a vulnerability in DDoS protection in Juniper Networks Junos OS and Junos OS Evolved on QFX5K Series switches in a VXLAN configuration, instability might be experienced in the underlay network as a consequence of exceeding the default ddos-protection aggregate threshold. If an attacker on a client device on the overlay network sends a high volume of specific, legitimate traffic in the overlay network, due to an improperly detected DDoS violation, the leaf might not process certain L2 traffic, sent by spines in the underlay network. Continued receipt and processing of the high volume traffic will sustain the Denial of Service (DoS) condition. This issue affects: Juniper Networks Junos OS on QFX5K Series: 17.3 versions prior to 17.3R3-S11; 17.4 versions prior to 17.4R3-S5; 18.1 versions prior to 18.1R3-S13; 18.2 versions prior to 18.2R2-S8, 18.2R3-S8; 18.3 versions prior to 18.3R3-S5; 18.4 versions prior to 18.4R1-S8, 18.4R2-S6, 18.4R3-S6; 19.1 versions prior to 19.1R3-S4; 19.2 versions prior to 19.2R1-S6, 19.2R3-S2; 19.3 versions prior to 19.3R3-S2; 19.4 versions prior to 19.4R2-S4, 19.4R3-S1; 20.1 versions prior to 20.1R2; 20.2 versions prior to 20.2R2; 20.3 versions prior to 20.3R1-S2, 20.3R2. Juniper Networks Junos OS Evolved on QFX5220: All versions prior to 20.3R2-EVO.
7.4
Haute
CVE-2021-0247 2021-04-22 19h37 +00:00 A Race Condition (Concurrent Execution using Shared Resource with Improper Synchronization) vulnerability in the firewall process (dfwd) of Juniper Networks Junos OS allows an attacker to bypass the firewall rule sets applied to the input loopback filter on any interfaces of a device. This issue is detectable by reviewing the PFE firewall rules, as well as the firewall counters and seeing if they are incrementing or not. For example: show firewall Filter: __default_bpdu_filter__ Filter: FILTER-INET-01 Counters: Name Bytes Packets output-match-inet 0 0 <<<<<< missing firewall packet count This issue affects: Juniper Networks Junos OS 14.1X53 versions prior to 14.1X53-D53 on QFX Series; 14.1 versions 14.1R1 and later versions prior to 15.1 versions prior to 15.1R7-S6 on QFX Series, PTX Series; 15.1X53 versions prior to 15.1X53-D593 on QFX Series; 16.1 versions prior to 16.1R7-S7 on QFX Series, PTX Series; 16.2 versions prior to 16.2R2-S11, 16.2R3 on QFX Series, PTX Series; 17.1 versions prior to 17.1R2-S11, 17.1R3-S2 on QFX Series, PTX Series; 17.2 versions prior to 17.2R1-S9, 17.2R3-S3 on QFX Series, PTX Series; 17.3 versions prior to 17.3R2-S5, 17.3R3-S7 on QFX Series, PTX Series; 17.4 versions prior to 17.4R2-S9, 17.4R3 on QFX Series, PTX Series; 18.1 versions prior to 18.1R3-S9 on QFX Series, PTX Series; 18.2 versions prior to 18.2R2-S6, 18.2R3-S3 on QFX Series, PTX Series; 18.3 versions prior to 18.3R1-S7, 18.3R2-S3, 18.3R3-S1 on QFX Series, PTX Series; 18.4 versions prior to 18.4R1-S5, 18.4R2-S3, 18.4R2-S7, 18.4R3 on QFX Series, PTX Series; 19.1 versions prior to 19.1R1-S4, 19.1R2-S1, 19.1R3 on QFX Series, PTX Series; 19.2 versions prior to 19.2R1-S3, 19.2R2 on QFX Series, PTX Series.
5.5
Moyen
CVE-2021-0237 2021-04-22 19h37 +00:00 On Juniper Networks EX4300-MP Series, EX4600 Series, EX4650 Series, QFX5K Series deployed as a Virtual Chassis with a specific Layer 2 circuit configuration, Packet Forwarding Engine manager (FXPC) process may crash and restart upon receipt of specific layer 2 frames. Continued receipt and processing of this packet will create a sustained Denial of Service (DoS) condition. This issue affects: Juniper Networks Junos OS on EX4300-MP Series, EX4600 Series, EX4650 Series, QFX5K Series 15.1 versions prior to 15.1R7-S9; 17.3 versions prior to 17.3R3-S11; 17.4 versions prior to 17.4R2-S13, 17.4R3-S4, 17.4R3-S5; 18.2 versions prior to 18.2R3-S8; 18.3 versions prior to 18.3R3-S4; 18.4 versions prior to 18.4R2-S7, 18.4R3-S6; 19.1 versions prior to 19.1R3-S4; 19.2 versions prior to 19.2R1-S6, 19.2R3-S1; 19.3 versions prior to 19.3R3-S1; 19.4 versions prior to 19.4R2-S4, 19.4R3-S1; 20.1 versions prior to 20.1R2; 20.2 versions prior to 20.2R2, 20.2R3; 20.3 versions prior to 20.3R1-S2, 20.3R2;
6.5
Moyen
CVE-2021-0217 2021-01-15 17h35 +00:00 A vulnerability in processing of certain DHCP packets from adjacent clients on EX Series and QFX Series switches running Juniper Networks Junos OS with DHCP local/relay server configured may lead to exhaustion of DMA memory causing a Denial of Service (DoS). Over time, exploitation of this vulnerability may cause traffic to stop being forwarded, or to crashing of the fxpc process. When Packet DMA heap utilization reaches 99%, the system will become unstable. Packet DMA heap utilization can be monitored through the following command: user@junos# request pfe execute target fpc0 timeout 30 command "show heap" ID Base Total(b) Free(b) Used(b) % Name -- ---------- ----------- ----------- ----------- --- ----------- 0 213301a8 536870488 387228840 149641648 27 Kernel 1 91800000 8388608 3735120 4653488 55 DMA 2 92000000 75497472 74452192 1045280 1 PKT DMA DESC 3 d330000 335544320 257091400 78452920 23 Bcm_sdk 4 96800000 184549376 2408 184546968 99 Packet DMA <--- 5 903fffe0 20971504 20971504 0 0 Blob An indication of the issue occurring may be observed through the following log messages: Dec 10 08:07:00.124 2020 hostname fpc0 brcm_pkt_buf_alloc:523 (buf alloc) failed allocating packet buffer Dec 10 08:07:00.126 2020 hostname fpc0 (buf alloc) failed allocating packet buffer Dec 10 08:07:00.128 2020 hostname fpc0 brcm_pkt_buf_alloc:523 (buf alloc) failed allocating packet buffer Dec 10 08:07:00.130 2020 hostnameC fpc0 (buf alloc) failed allocating packet buffer This issue affects Juniper Networks Junos OS on EX Series and QFX Series: 17.4R3 versions prior to 17.4R3-S3; 18.1R3 versions between 18.1R3-S6 and 18.1R3-S11; 18.2R3 versions prior to 18.2R3-S6; 18.3R3 versions prior to 18.3R3-S4; 18.4R2 versions prior to 18.4R2-S5; 18.4R3 versions prior to 18.4R3-S6; 19.1 versions between 19.1R2 and 19.1R3-S3; 19.2 versions prior to 19.2R3-S1; 19.3 versions prior to 19.3R2-S5, 19.3R3; 19.4 versions prior to 19.4R2-S2, 19.4R3; 20.1 versions prior to 20.1R2; 20.2 versions prior to 20.2R1-S2, 20.2R2. Junos OS versions prior to 17.4R3 are unaffected by this vulnerability.
7.4
Haute
CVE-2021-0207 2021-01-15 17h35 +00:00 An improper interpretation conflict of certain data between certain software components within the Juniper Networks Junos OS devices does not allow certain traffic to pass through the device upon receipt from an ingress interface filtering certain specific types of traffic which is then being redirected to an egress interface on a different VLAN. This causes a Denial of Service (DoS) to those clients sending these particular types of traffic. Such traffic being sent by a client may appear genuine, but is non-standard in nature and should be considered as potentially malicious, and can be targeted to the device, or destined through it for the issue to occur. This issues affects IPv4 and IPv6 traffic. An indicator of compromise may be found by checking log files. You may find that traffic on the input interface has 100% of traffic flowing into the device, yet the egress interface shows 0 pps leaving the device. For example: [show interfaces "interface" statistics detail] Output between two interfaces would reveal something similar to: Ingress, first interface: -------------------- Interface Link Input packets (pps) Output packets (pps) et-0/0/0 Up 9999999999 (9999) 1 (0) -------------------- Egress, second interface: -------------------- Interface Link Input packets (pps) Output packets (pps) et-0/0/1 Up 0 (0) 9999999999 (0) -------------------- Dropped packets will not show up in DDoS monitoring/protection counters as issue is not caused by anti-DDoS protection mechanisms. This issue affects: Juniper Networks Junos OS: 17.3 versions prior to 17.3R3-S7 on NFX250, QFX5K Series, EX4600; 17.4 versions prior to 17.4R2-S11, 17.4R3-S3 on NFX250, QFX5K Series, EX4600; 18.1 versions prior to 18.1R3-S9 on NFX250, QFX5K Series, EX2300 Series, EX3400 Series, EX4600; 18.2 versions prior to 18.2R3-S3 on NFX250, QFX5K Series, EX2300 Series, EX3400 Series, EX4300 Multigigabit, EX4600; 18.3 versions prior to 18.3R3-S1 on NFX250, QFX5K Series, EX2300 Series, EX3400 Series, EX4300 Multigigabit, EX4600 Series; 18.4 versions prior to 18.4R1-S5, 18.4R2-S3, 18.4R3 on NFX250, QFX5K Series, EX2300 Series, EX3400 Series, EX4300 Multigigabit, EX4600 Series; 19.1 versions prior to 19.1R1-S5, 19.1R2-S1, 19.1R3 on NFX250, QFX5K Series, EX2300 Series, EX3400 Series, EX4300 Multigigabit, EX4600 Series; 19.2 versions prior to 19.2R1-S5, 19.2R2 on NFX250, QFX5K Series, EX2300 Series, EX3400 Series, EX4300 Multigigabit, EX4600 Series; 19.3 versions prior to 19.3R2-S3, 19.3R3 on NFX250, QFX5K Series, EX2300 Series, EX3400 Series, EX4300 Multigigabit, EX4600 Series; 19.4 versions prior to 19.4R1-S2, 19.4R2 on NFX250, NFX350, QFX5K Series, EX2300 Series, EX3400 Series, EX4300 Multigigabit, EX4600 Series. This issue does not affect Junos OS releases prior to 17.2R2.
7.5
Haute
CVE-2021-0203 2021-01-15 17h35 +00:00 On Juniper Networks EX and QFX5K Series platforms configured with Redundant Trunk Group (RTG), Storm Control profile applied on the RTG interface might not take affect when it reaches the threshold condition. Storm Control enables the device to monitor traffic levels and to drop broadcast, multicast, and unknown unicast packets when a specified traffic level is exceeded, thus preventing packets from proliferating and degrading the LAN. Note: this issue does not affect EX2200, EX3300, EX4200, and EX9200 Series. This issue affects Juniper Networks Junos OS on EX Series and QFX5K Series: 15.1 versions prior to 15.1R7-S7; 16.1 versions prior to 16.1R7-S8; 17.2 versions prior to 17.2R3-S4; 17.3 versions prior to 17.3R3-S8; 17.4 versions prior to 17.4R2-S11, 17.4R3-S2; 18.1 versions prior to 18.1R3-S10; 18.2 versions prior to 18.2R3-S5; 18.3 versions prior to 18.3R2-S4, 18.3R3-S2; 18.4 versions prior to 18.4R2-S5, 18.4R3-S3; 19.1 versions prior to 19.1R2-S2, 19.1R3-S2; 19.2 versions prior to 19.2R1-S5, 19.2R2-S1, 19.2R3; 19.3 versions prior to 19.3R2-S4, 19.3R3; 19.4 versions prior to 19.4R1-S3, 19.4R2-S1, 19.4R3; 20.1 versions prior to 20.1R1-S2, 20.1R2.
8.6
Haute
CVE-2020-1689 2020-10-16 20h31 +00:00 On Juniper Networks EX4300-MP Series, EX4600 Series and QFX5K Series deployed in a Virtual Chassis configuration, receipt of a stream of specific layer 2 frames can cause high CPU load, which could lead to traffic interruption. This issue does not occur when the device is deployed in Stand Alone configuration. The offending layer 2 frame packets can originate only from within the broadcast domain where the device is connected. This issue affects Juniper Networks Junos OS on EX4300-MP Series, EX4600 Series and QFX5K Series: 17.3 versions prior to 17.3R3-S9; 17.4 versions prior to 17.4R2-S11, 17.4R3-S2, 17.4R3-S3; 18.1 versions prior to 18.1R3-S11; 18.2 versions prior to 18.2R3-S5; 18.3 versions prior to 18.3R2-S4, 18.3R3-S3; 18.4 versions prior to 18.4R2-S5, 18.4R3-S4; 19.1 versions prior to 19.1R3-S2; 19.2 versions prior to 19.2R1-S5, 19.2R3; 19.3 versions prior to 19.3R2-S4, 19.3R3; 19.4 versions prior to 19.4R1-S3, 19.4R2-S1, 19.4R3; 20.1 versions prior to 20.1R1-S3, 20.1R2.
6.5
Moyen
CVE-2020-1685 2020-10-16 20h31 +00:00 When configuring stateless firewall filters in Juniper Networks EX4600 and QFX 5000 Series devices using Virtual Extensible LAN protocol (VXLAN), the discard action will fail to discard traffic under certain conditions. Given a firewall filter configuration similar to: family ethernet-switching { filter L2-VLAN { term ALLOW { from { user-vlan-id 100; } then { accept; } } term NON-MATCH { then { discard; } } when there is only one term containing a 'user-vlan-id' match condition, and no other terms in the firewall filter except discard, the discard action for non-matching traffic will only discard traffic with the same VLAN ID specified under 'user-vlan-id'. Other traffic (e.g. VLAN ID 200) will not be discarded. This unexpected behavior can lead to unintended traffic passing through the interface where the firewall filter is applied. This issue only affects systems using VXLANs. This issue affects Juniper Networks Junos OS on QFX5K Series: 18.1 versions prior to 18.1R3-S7, except 18.1R3; 18.2 versions prior to 18.2R2-S7, 18.2R3-S1; 18.3 versions prior to 18.3R1-S5, 18.3R2-S4, 18.3R3; 18.4 versions prior to 18.4R1-S7, 18.4R2-S1, 18.4R3; 19.1 versions prior to 19.1R1-S5, 19.1R2; 19.2 versions prior to 19.2R1-S5, 19.2R2.
5.8
Moyen
CVE-2020-1679 2020-10-16 20h31 +00:00 On Juniper Networks PTX and QFX Series devices with packet sampling configured using tunnel-observation mpls-over-udp, sampling of a malformed packet can cause the Kernel Routing Table (KRT) queue to become stuck. KRT is the module within the Routing Process Daemon (RPD) that synchronized the routing tables with the forwarding tables in the kernel. This table is then synchronized to the Packet Forwarding Engine (PFE) via the KRT queue. Thus, when KRT queue become stuck, it can lead to unexpected packet forwarding issues. An administrator can monitor the following command to check if there is the KRT queue is stuck: user@device > show krt state ... Number of async queue entries: 65007 <--- this value keep on increasing. When this issue occurs, the following message might appear in the /var/log/messages: DATE DEVICE kernel: %KERN-3: rt_pfe_veto: Too many delayed route/nexthop unrefs. Op 2 err 55, rtsm_id 5:-1, msg type 2 DATE DEVICE kernel: %KERN-3: rt_pfe_veto: Memory usage of M_RTNEXTHOP type = (0) Max size possible for M_RTNEXTHOP type = (7297134592) Current delayed unref = (60000), Current unique delayed unref = (18420), Max delayed unref on this platform = (40000) Current delayed weight unref = (60000) Max delayed weight unref on this platform= (400000) curproc = rpd This issue affects Juniper Networks Junos OS on PTX/QFX Series: 17.2X75 versions prior to 17.2X75-D105; 18.1 versions prior to 18.1R3-S11; 18.2 versions prior to 18.2R3-S5; 18.2X75 versions prior to 18.2X75-D420, 18.2X75-D53, 18.2X75-D65; 18.3 versions prior to 18.3R2-S4, 18.3R3-S3; 18.4 versions prior to 18.4R1-S7, 18.4R2-S5, 18.4R3-S4; 19.1 versions prior to 19.1R2-S2, 19.1R3-S2; 19.2 versions prior to 19.2R1-S5, 19.2R3; 19.3 versions prior to 19.3R2-S3, 19.3R3; 19.4 versions prior to 19.4R1-S2, 19.4R2-S1, 19.4R3; 20.1 versions prior to 20.1R1-S2, 20.1R2. This issue does not affect Juniper Networks Junos OS prior to 18.1R1.
7.5
Haute
CVE-2020-1661 2020-10-16 20h31 +00:00 On Juniper Networks Junos OS devices configured as a DHCP forwarder, the Juniper Networks Dynamic Host Configuration Protocol Daemon (jdhcp) process might crash when receiving a malformed DHCP packet. This issue only affects devices configured as DHCP forwarder with forward-only option, that forward specified DHCP client packets, without creating a new subscriber session. The jdhcpd daemon automatically restarts without intervention, but continuous receipt of the malformed DHCP packet will repeatedly crash jdhcpd, leading to an extended Denial of Service (DoS) condition. This issue can be triggered only by DHCPv4, it cannot be triggered by DHCPv6. This issue affects Juniper Networks Junos OS: 12.3 versions prior to 12.3R12-S16; 12.3X48 versions prior to 12.3X48-D105 on SRX Series; 14.1X53 versions prior to 14.1X53-D60 on EX and QFX Series; 15.1 versions prior to 15.1R7-S7; 15.1X49 versions prior to 15.1X49-D221, 15.1X49-D230 on SRX Series; 15.1X53 versions prior to 15.1X53-D593 on EX2300/EX3400; 16.1 versions prior to 16.1R7-S5.
5.3
Moyen