Schneider Electric EcoStruxure Control Expert 15.2

CPE Details

Schneider Electric EcoStruxure Control Expert 15.2
15.2
2025-01-16
13h45 +00:00
2025-01-16
13h45 +00:00
Alerte pour un CPE
Stay informed of any changes for a specific CPE.
Notifications manage

CPE Name: cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.2:*:*:*:*:*:*:*

Informations

Vendor

schneider-electric

Product

ecostruxure_control_expert

Version

15.2

Related CVE

Open and find in CVE List

CVE ID Published Description Score Severity
CVE-2023-27975 2024-02-14 16h55 +00:00 CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause unauthorized access to the project file in EcoStruxure Control Expert when a local user tampers with the memory of the engineering workstation.
7.1
High
CVE-2023-6408 2024-02-14 16h52 +00:00 CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause a denial of service and loss of confidentiality, integrity of controllers when conducting a Man in the Middle attack.
8.1
High
CVE-2023-6409 2024-02-14 16h47 +00:00 CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause unauthorized access to a project file protected with application password when opening the file with EcoStruxure Control Expert.
7.7
High
CVE-2023-1548 2023-04-18 16h42 +00:00 A CWE-269: Improper Privilege Management vulnerability exists that could cause a local user to perform a denial of service through the console server service that is part of EcoStruxure Control Expert. Affected Products: EcoStruxure Control Expert (V15.1 and above)
5.5
Medium
CVE-2023-27976 2023-04-18 16h39 +00:00 A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause remote code execution when a valid user visits a malicious link provided through the web endpoints. Affected Products: EcoStruxure Control Expert (V15.1 and above)
8.8
High
CVE-2022-45789 2023-01-31 00h00 +00:00 A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions)
9.8
Critical
CVE-2022-45788 2023-01-30 00h00 +00:00 A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions), Modicon Momentum Unity M1E Processor - 171CBU* (All Versions), Modicon MC80 - BMKC80 (All Versions), Legacy Modicon Quantum - 140CPU65* and Premium CPUs - TSXP57* (All Versions)
9.8
Critical
CVE-2020-7560 2020-12-10 23h52 +00:00 A CWE-123: Write-what-where Condition vulnerability exists in EcoStruxure™ Control Expert (all versions) and Unity Pro (former name of EcoStruxure™ Control Expert) (all versions), that could cause a crash of the software or unexpected code execution when opening a malicious file in EcoStruxure™ Control Expert software.
8.6
High
CVE-2020-7559 2020-11-19 20h04 +00:00 A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted request over Modbus.
7.5
High
CVE-2020-7538 2020-11-19 20h04 +00:00 A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted request over Modbus.
7.5
High
CVE-2020-28213 2020-11-19 20h03 +00:00 A CWE-494: Download of Code Without Integrity Check vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when sending specially crafted requests over Modbus.
8.8
High
CVE-2020-28212 2020-11-19 20h03 +00:00 A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when a brute force attack is done over Modbus.
9.8
Critical
CVE-2020-28211 2020-11-19 20h03 +00:00 A CWE-863: Incorrect Authorization vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause bypass of authentication when overwriting memory using a debugger.
7.8
High