CVE Descriptions

The web server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote attackers to cause a denial of service (reboot) via malformed HTTP requests.

CVE Informations

Related Weaknesses

CWE-ID Weakness Name Source
CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
The product uses external input to construct a pathname that is intended to identify a file or directory that is located underneath a restricted parent directory, but the product does not properly neutralize special elements within the pathname that can cause the pathname to resolve to a location that is outside of the restricted directory.

Metrics

Metrics Score Severity CVSS Vector Source
V2 7.8 AV:N/AC:L/Au:N/C:N/I:N/A:C [email protected]

EPSS

EPSS is a scoring model that predicts the likelihood of a vulnerability being exploited.

EPSS Score

The EPSS model produces a probability score between 0 and 1 (0 and 100%). The higher the score, the greater the probability that a vulnerability will be exploited.

EPSS Percentile

The percentile is used to rank CVE according to their EPSS score. For example, a CVE in the 95th percentile according to its EPSS score is more likely to be exploited than 95% of other CVE. Thus, the percentile is used to compare the EPSS score of a CVE with that of other CVE.

Products Mentioned

Configuraton 0

Siemens>>Scalance_x-300_series_firmware >> Version To (including) 3.9.3

Siemens>>Scalance_x-300 >> Version -

Siemens>>Scalance_x-300eec >> Version -

Siemens>>Scalance_x-300poe >> Version -

Siemens>>Scalance_xr-300 >> Version -

Siemens>>Scalance_xr-300eec >> Version -

Siemens>>Scalance_xr-300poe >> Version -

Configuraton 0

Siemens>>Scalance_x-408_firmware >> Version To (including) 3.9.3

Siemens>>Scalance_x-408 >> Version *

References