CWE-1280 Detail

CWE-1280

Access Control Check Implemented After Asset is Accessed
Incomplete
2020-02-24 00:00 +00:00
2023-10-26 00:00 +00:00

Alerte pour un CWE

Stay informed of any changes for a specific CWE.
Alert management

Access Control Check Implemented After Asset is Accessed

A product's hardware-based access control check occurs after the asset has been accessed.

Extended Description

The product implements a hardware-based access control check. The asset should be accessible only after the check is successful. If, however, this operation is not atomic and the asset is accessed before the check is complete, the security of the system may be compromised.

Informations

Modes Of Introduction

Implementation

Applicable Platforms

Language

Name: Verilog (Undetermined)
Name: VHDL (Undetermined)
Class: Not Language-Specific (Undetermined)

Operating Systems

Class: Not OS-Specific (Undetermined)

Architectures

Class: Not Architecture-Specific (Undetermined)

Technologies

Class: Not Technology-Specific (Undetermined)

Common Consequences

Scope Impact Likelihood
Access Control
Confidentiality
Integrity
Modify Memory, Read Memory, Modify Application Data, Read Application Data, Gain Privileges or Assume Identity, Bypass Protection Mechanism

Potential Mitigations

Phases : Implementation
Implement the access control check first. Access should only be given to asset if agent is authorized.

Vulnerability Mapping Notes

Rationale : This CWE entry is at the Base level of abstraction, which is a preferred level of abstraction for mapping to the root causes of vulnerabilities.
Comments : Carefully read both the name and description to ensure that this mapping is an appropriate fit. Do not try to 'force' a mapping to a lower-level Base/Variant simply to comply with this preferred level of abstraction.

Related Attack Patterns

CAPEC-ID Attack Pattern Name
CAPEC-180 Exploiting Incorrectly Configured Access Control Security Levels
An attacker exploits a weakness in the configuration of access controls and is able to bypass the intended protection that these measures guard against and thereby obtain unauthorized access to the system or network. Sensitive functionality should always be protected with access controls. However configuring all but the most trivial access control systems can be very complicated and there are many opportunities for mistakes. If an attacker can learn of incorrectly configured access security settings, they may be able to exploit this in an attack.

Submission

Name Organization Date Date Release Version
Arun Kanuparthi, Hareesh Khattri, Parbati Kumar Manna, Narasimha Kumar V Mangipudi Intel Corporation 2020-02-12 +00:00 2020-02-24 +00:00 4.1

Modifications

Name Organization Date Comment
CWE Content Team MITRE 2020-08-20 +00:00 updated Applicable_Platforms, Demonstrative_Examples, Description, Related_Attack_Patterns
CWE Content Team MITRE 2022-10-13 +00:00 updated Demonstrative_Examples
CWE Content Team MITRE 2023-04-27 +00:00 updated Relationships
CWE Content Team MITRE 2023-06-29 +00:00 updated Mapping_Notes
CWE Content Team MITRE 2023-10-26 +00:00 updated Demonstrative_Examples
Click on the button to the left (OFF), to authorize the inscription of cookie improving the functionalities of the site. Click on the button to the left (Accept all), to unauthorize the inscription of cookie improving the functionalities of the site.